To identify the most appropriate system for your project consider the following:
What is the substrate?
Concrete base; Acoustic battens may be laid directly on the concrete base. Where Impact 18 is installed a levelling screed should be laid.
Timber frame building; Tri-batten is designed specifically for use in timber frame building.
Traditional timber joisted sub-floor; Decks and Acoustic Strip Systems are designed to enhance new and old timber base constructions, with a masonry facade.
Is there an existing floor to be retained?
Acoustic Strip and primary Deck Systems are designed for use where the existing floor is to be retained. Acoustic Strip is designed for new projects and projects where the joists are exposed.
Is the finished floor height critical?
Deck 9 System is designed for projects where a minimal increase in floor height is required.
What performance does your project require?
Use the Monarfloor solutions selector below to assist your decision.
If you know your product choose from the contents list, if you are unsure, use our application table below to decide which Monarfloor product is most suited to your particular application.
| Monarfloor Solutions Selector | ||||
|---|---|---|---|---|
| Concrete base | Concrete planks |
Solid slab |
Solid slab + permanent shutter |
Beam and block |
| Deck 9 | ||||
| Deck 18 | ||||
| Deck 22 | ||||
| Impact 18 |
(3) |
(3) |
(3) |
(3) |
| Structure Deck | ||||
| Tri- Deck | ||||
| Deep Acoustic Batten |
(3) |
(3) |
(3) |
(3) |
| Shallow Acoustic Tri-Batten |
||||
| Acoustic Strip | ||||
| Acoustic Cradle | ||||
| Timber base | Timber framed buildings |
New project | Floor to remain, height not critical (masonry facade) |
Floor to remain, height critical (masonry facade) |
Floor to be removed |
| Deck 9 |
(1) |
||||
| Deck 18 |
(1) |
||||
| Deck 22 |
(1) |
||||
| Impact 18 | |||||
| Structure Deck |
(1) |
||||
| Tri- Deck |
(2) |
||||
| Deep Acoustic Batten |
(1) |
||||
| Shallow Acoustic Tri-Batten |
(1) |
||||
| Acoustic Strip |
(1) |
||||
| Acoustic Cradle |
| Steel Joist base | New project |
| Deck 9 | |
| Deck 18 |
(1) |
| Deck 22 | |
| Impact 18 | |
| Structure Deck | |
| Tri- Deck | |
| Deep Acoustic Batten |
|
| Shallow Acoustic Tri-Batten |
|
| Acoustic Strip | |
| Acoustic Cradle |
(1) this system to be used in conjunction with a resilient bar ceiling
(2) this system does not require a resilient bar ceiling
(3) this system to be used in conjunction with either resilient bar
or metal framed ceiling, depending on application